| Product Name | Water Catalyst Electrolytic Cell | Brand Name | HOMIXE |
| Model Number | HM-FPC287215 | Feature | Hydroxyl radical (·OH) purification with water only; no salt, no chemicals, no additives; stable cell voltage; low power consumption |
| Grade | GR1 Titanium | Technique | Rolling, Cutting, Welding, Painting |
| Application | Fruit & vegetable purifiers; Food purifiers; Fresh-cut & central kitchen equipment; Commercial food-washing machines | Dimension | Customization |
| Coating | Ru-Ir Ir-Ta Platinum | Coating Thickness | 8~12micron |
| Product Name | Water Catalyst Electrolytic Cell | Brand Name | HOMIXE |
| Model Number | HM-FPC287215 | Feature | Hydroxyl radical (·OH) purification with water only; no salt, no chemicals, no additives; stable cell voltage; low power consumption |
| Grade | GR1 Titanium | Technique | Rolling, Cutting, Welding, Painting |
| Application | Fruit & vegetable purifiers; Food purifiers; Fresh-cut & central kitchen equipment; Commercial food-washing machines | Dimension | Customization |
| Coating | Ru-Ir Ir-Ta Platinum | Coating Thickness | 8~12micron |

This is the highest-output electrode assembly in the range, and the most open: fifteen anodes, all coated, clamped on M12 x 65 mm tie rods and supplied without a housing so the reactor body, porting and sealing are the equipment maker's design. It is chosen by OEMs who want maximum oxidant output per litre of cell volume and who already machine titanium or plastic reactor bodies in house. Because every plate is an anode, output does not fall away along the stack, and because each plate is independent, coating wear is a maintenance item rather than an assembly replacement.
Fifteen independent anodes on M12 tie rods: the highest active area we supply, for OEMs who want the reactor body to be their own design.
How Hydroxyl Radicals Purify Your Produce


Tap, purified or mineral water fills the purification tank. No salt, no chemicals, no additives.


A DC field across the coated titanium electrodes splits water molecules into hydrogen ions (H⁺) and hydroxide ions (OH⁻).


Short-lived hydroxyl radicals (·OH) form at the catalytic surface; micro-bubbles improve contact with the food surface.


·OH breaks the covalent bonds of pesticide, hormone and antibiotic residues, and disrupts microbial cell walls.


Radicals revert to water within seconds. End products: water, CO₂ and inorganic salts — no chemical residue.
KEY PERFORMANCE DATA








COMPLIANCE & CERTIFICATION
Designed around the standards your machine must meet
![]() |
|
Performance table
| Metric | Value | Test method |
| Pesticide residue degradation | ≥ 95% | Spiked-sample degradation test, GB |
| Microbial inactivation | > 99.99% | Suspension and carrier quantitative |
| Virus inactivation | > 99.99% | Virus inactivation test |
| Hormone / antibiotic degradation | 93–98% | Spiked-sample degradation test |
| Protein retention | 99.5% | GB 5009.5 |
| Vitamin C retention | 97.8% | GB 5009.86 |
| ORP lift | ≥ +300 mV | ORP meter, 25 °C, before/after |
| ORP after treatment | ≥ +750 mV | Same as above |
| Oxidation potential of ·OH | 2.8 V | Physical constant |
| Purification cycle | 5–15 min | Per machine configuration |
| Ozone emission | ≤ 0.16 mg/m³ | SB/T 11190-2017 |
| Continuous operation | ≤ 0.16 mg/m³ | SB/T 11190-2017 |
Performance figures reflect published industry levels for water-only food purification systems and are provided for reference. Product-specific test reports are supplied with samples and quotations.


The purification core module for household and commercial washers.


Continuous-duty cells for washing and production lines.


Scalable from single-tank units to industrial systems.


Water and wastewater treatment equipment.
Comparing the four purification routes used in fruit and vegetable washers
| Feature | Water Catalyst (·OH) | Ozone | Ultrasonic |
| Purification agent | Hydroxyl radical (·OH) | O₃ gas | Cavitation |
| Chemical addition | None | None | None |
| Pesticide residue degradation | High | Medium to high | Surface residue only |
| Contact with produce | Full immersion | Gas phase | Water bath |
| Nutrient retention | High | May oxidise vitamin C | High |
| Airborne emission | None | Ozone limit ≤ 0.16 mg/m³ | None |
| Main service part | Electrode coating | Ozone generator | Transducer |
| Fits SB/T 11190-2017 | ✓ | Within ozone limits | Ultrasound 20–50 kHz |
Most cells on the market are assembled from bought-in electrodes. HOMIXE is different: we are the anode factory.

The electrode is our own product. Every HOMIXE cell is built around coated titanium anodes we manufacture ourselves — oxygen-evolution iridium-tantalum (IrO₂–Ta₂O₅) or platinum on GR1 titanium, with an 8–12 μm coating. The coating governs purification performance and cell life, so making it in-house means a longer-lasting cell under our own quality control, at factory-direct cost.
Proven in electrodes.trusted by OEMs. For years we have supplied coated titanium anodes and electrolytic cells to purifier and electrolyzer manufacturers worldwide — the same electrodes now running inside our own cells.
Tailored, not off-the-shelf. Electrode count, cell size, voltage, flow path and duty cycle are configured to your tank and power board. Private-label and OEM/ODM programs welcome.
Backed after the sale. ISO9001, RoHS, CE and SGS certified, with a 1 month warranty — and because we make the electrodes, replacement cells are stocked in the same factory for fast re-supply.
OEM & Customized Solutions
Different projects require different electrode dimensions, coating systems, cell structures and electrical configurations. HOMIXE supports customized solutions for OEM manufacturers, water treatment companies and system integrators.








For water treatment projects and complete disinfection systems


For OEM equipment manufacturers and system integrators


For electrolysis system replacement and customized applications