OEM Water Catalyst Electrolytic Cell - Bare Electrode Stack

Delivered as an open electrode stack, this 11-plate cell is for purifier makers who machine their own housing. Eleven 1.0 mm TA1 titanium plates run on M14 tie rods across a 280 mm active plate height, in a footprint only 72 mm wide. Supplied uncased, it is the lowest-cost route to a water-only hydroxyl-radical purification core, and the usual starting point for prototypes, sample units and compact countertop builds. Plate count and spacing can be adjusted to your reactor.

Samples:

1-10 piece

Shipping:

PAD, By air, Sea freight

Place of Origin:

Foshan China

Payments:

L/C,D/A,D/P,T/T,Western Union,MoneyGram,OA

Lead Time:

7-10 days

Customization:

Customized logo (Min. Order: 100 sets),Customized packaging (Min. Order: 500 sets),Graphic customization (Min. Order: 500 sets)

Services:

OEM,ODM

Certificate:

ISO9001, RoSH, SGS

×
Product NameWater Catalyst Electrolytic CellBrand NameHOMIXE
Model NumberHM-FPC287211FeatureHydroxyl radical (·OH) purification with water only; no salt, no chemicals, no additives; stable cell voltage; low power consumption
GradeGR1 TitaniumTechniqueRolling, Cutting, Welding, Painting
ApplicationFruit & vegetable purifiers; Food purifiers; Fresh-cut & central kitchen equipment; Commercial food-washing machinesDimensionCustomization
CoatingRu-Ir Ir-Ta PlatinumCoating Thickness8~12micron


Product Details▼
Product NameWater Catalyst Electrolytic CellBrand NameHOMIXE
Model NumberHM-FPC287211FeatureHydroxyl radical (·OH) purification with water only; no salt, no chemicals, no additives; stable cell voltage; low power consumption
GradeGR1 TitaniumTechniqueRolling, Cutting, Welding, Painting
ApplicationFruit & vegetable purifiers; Food purifiers; Fresh-cut & central kitchen equipment; Commercial food-washing machinesDimensionCustomization
CoatingRu-Ir Ir-Ta PlatinumCoating Thickness8~12micron


How Hydroxyl Radicals Purify Your Produce

01 Water Intake01 Water Intake

01 Water Intake

Tap, purified or mineral water fills the purification tank. No salt, no chemicals, no additives.

02 Electrolysis02 Electrolysis

02 Electrolysis

A DC field across the coated titanium electrodes splits water molecules into hydrogen ions (H⁺) and hydroxide ions (OH⁻).

03 Hydroxyl Radical Generation03 Hydroxyl Radical Generation

03 Hydroxyl Radical Generation

Short-lived hydroxyl radicals (·OH) form at the catalytic surface; micro-bubbles improve contact with the food surface.

04 Degradation & Inactivation04 Degradation & Inactivation

04 Degradation & Inactivation

·OH breaks the covalent bonds of pesticide, hormone and antibiotic residues, and disrupts microbial cell walls.

05 Return to Water05 Return to Water

05 Return to Water

Radicals revert to water within seconds. End products: water, CO₂ and inorganic salts — no chemical residue.

KEY PERFORMANCE DATA

≥ 95% Pesticide residue degradation≥ 95% Pesticide residue degradation
≥ 95% Pesticide residue degradation
> 99.99% Microbial inactivation> 99.99% Microbial inactivation
> 99.99% Microbial inactivation
≥ +300 mV  ORP lift≥ +300 mV  ORP lift
≥ +300 mV ORP lift
10 min Purification cycle10 min Purification cycle
10 min Purification cycle

COMPLIANCE & CERTIFICATION


Designed around the standards your machine must meet

证书4 拷贝.jpg
  • SB/T 11190-2017

    Fruit and Vegetable Purification Washing Machines. The standard explicitly excludes equipment that requires added cleaning or disinfecting agents, so purification with water alone is fully within scope.

  • QB/T 8050-2024

    Household and similar fruit and vegetable washers.


  • GB 4706.1

    Safety of household and similar electrical appliances.


  • Factory certifications:

    ISO 9001 · RoHS · CE · SGS


Performance table

MetricValueTest method
Pesticide residue degradation≥ 95%Spiked-sample degradation test, GB
Microbial inactivation> 99.99%Suspension and carrier quantitative
Virus inactivation> 99.99%Virus inactivation test
Hormone / antibiotic degradation93–98%Spiked-sample degradation test
Protein retention99.5%GB 5009.5
Vitamin C retention97.8%GB 5009.86
ORP lift≥ +300 mVORP meter, 25 °C, before/after
ORP after treatment≥ +750 mVSame as above
Oxidation potential of ·OH2.8 VPhysical constant
Purification cycle5–15 minPer machine configuration
Ozone emission≤ 0.16 mg/m³SB/T 11190-2017
Continuous operation≤ 0.16 mg/m³SB/T 11190-2017

Performance figures reflect published industry levels for water-only food purification systems and are provided for reference. Product-specific test reports are supplied with samples and quotations.


Application Scenario

Fruit & Vegetable PurifiersFruit & Vegetable Purifiers

Fruit & Vegetable Purifiers

The purification core module for household and commercial washers.

Fresh-cut & Central KitchenFresh-cut & Central Kitchen

Fresh-cut & Central Kitchen

Continuous-duty cells for washing and production lines.

Commercial & Industrial Food PurificationCommercial & Industrial Food Purification

Commercial & Industrial Food Purification

Scalable from single-tank units to industrial systems.

Water TreatmentWater Treatment

Water Treatment

Water and wastewater treatment equipment.

Water Catalyst Technology vs. Other Purification Methods

Comparing the four purification routes used in fruit and vegetable washers


FeatureWater Catalyst (·OH)OzoneUltrasonic
Purification agentHydroxyl radical (·OH)O₃ gasCavitation
Chemical additionNoneNoneNone
Pesticide residue degradationHighMedium to highSurface residue only
Contact with produceFull immersionGas phaseWater bath
Nutrient retentionHighMay oxidise vitamin CHigh
Airborne emissionNoneOzone limit ≤ 0.16 mg/m³None
Main service partElectrode coatingOzone generatorTransducer
Fits SB/T 11190-2017✓Within ozone limitsUltrasound 20–50 kHz




Why Buy Water Catalyst Electrolytic Cells from HOMIXE?

Most cells on the market are assembled from bought-in electrodes. HOMIXE is different: we are the anode factory.

OEM & Customized Solutions

Different projects require different electrode dimensions, coating systems, cell structures and electrical configurations. HOMIXE supports customized solutions for OEM manufacturers, water treatment companies and system integrators.

Custom Electrode DesignCustom Electrode Design

Custom Electrode Design

Custom Coating SystemCustom Coating System

Custom Coating System

Custom Cell StructureCustom Cell Structure

Custom Cell Structure

Choose Your Solution

Sodium Hypochlorite GeneratorSodium Hypochlorite Generator

Sodium Hypochlorite Generator

For water treatment projects and complete disinfection systems

Titanium Electrolytic CellTitanium Electrolytic Cell

Titanium Electrolytic Cell

For OEM equipment manufacturers and system integrators

MMO Titanium AnodeMMO Titanium Anode

MMO Titanium Anode

For electrolysis system replacement and customized applications


Online feedback
Or please use the following table for reference. Our sales representative will contact you within 24 hours. Thank you for your attention to our products
*
Name
*
Phone
*
Email @
*
Choose country
*
Content

FAQ